ICOM firmware upgrade instructions

1. Connect the ICOM to the computer with a network cable, and power up the ICOM with a 12V power adapter or

Passengers pick up the bus.

2.Use IE browser to open http://169.254.92.38:60080/ (when diagnosing according to ICOM

The IP address shown or the ICOM address read by ItoolRadar shall prevail), user name/

Password: root/NZY11502

3.Click “Update Firmware” and you will see the version information of ICOM firmware.

4.Choice ICOM-BootImage-01-24-00.bin ( Upgrade file path: C:/Program Files(x86)/Tools/Icom-ApplicationImage-01-41-00c),“ image type“ Set to“SYSTEM“, click “Send the file”。

5.When it prompts “Write the image file to the flash?” , click “Yes”, and then the lights will turn red.

6.When it prompts “The SYSTEM IMAGE update was successfull”,click”Update Firmware”。

7.Select icom-applicationimage-01-38-01.bin and set image type to APPLICATION, click “Send the file”, the file will take a few minutes.

8.When it prompts “Write the image file to the flash?” , click “Yes”, and then the lantern festival turned red for the second time.

9.When it is all right, click “reboot”. Upgrade complete