If you need to initialize the EGR cooler exchange process, it must be performed using SerDia2010 after the EGR cooler has been replaced.
Related Contents:
2023 Deutz Serdia2010 v14.1.9.1 Diagnostic Software Free Download
Deutz Diagnostic Kit DECOM for Deutz Engine
Handling the EGR Cooler Exchange for Deutz BR 2.9 and 3.6 T4i DOConly Engines
When replacing the EGR cooler, it’s essential to store the exchange moment (operating hours) in the engine control unit. This step reinitializes the term-dependent aging function of the EGR cooler.
Steps to Perform the EGR Cooler Exchange
- Press the “Set time cooler exchange” Button:
- Verify Operation Completion:
Consequences of Incorrect Initialization
Failure to initialize or incorrect initialization of the term-dependent aging function of the EGR cooler can lead to the following issues:
- EGR Cooler Changed Without Runtime Adjustment in the Control Unit:
- EGR correction is not active.
- High smoke values.
- Particulate emissions are exceeded.
- Potential lack of power.
- EGR Cooler Not Changed and Term-Dependent Aging Function Still Activated:
- EGR correction is active.
- High NOx emissions (exceeding the limit).
Additional Information
For more detailed information and troubleshooting, please refer to the https://www.autonumen.com/blog/category/deutz-engine-repair/